BTSHL - OXYGEN, REFRIGERATED LIQUID

  • MSDS: BTSHL
  • Manufacturer: U S AIRGAS INC
  • Product Name: OXYGEN, REFRIGERATED LIQUID
  • National Stock Number: 6830-01-049-5263
Product Identification

Product ID:OXYGEN, REFRIGERATED LIQUID
MSDS Date:05/20/1996
FSC:6830
NIIN:01-049-5263
MSDS Number: BTSHL

Responsible Party
U S AIRGAS INC.
100 MATSONFORD ROAD SUITE 550
RADNOR, PA 19087
US

Emergency Phone: 800-424-9300(CHEMTREC)/202-483-7616

Info Phone: 610-687-5253

Preparer: P-0043)

Cage: 0MN39

Contractor
AIRGAS INC
WAYNE, PA 19087 US

Telephone: 215-687-5253

Cage: 0MN39

Ingredients

OXYGEN

CAS: 7782-44-7

RTECS: RS2060000

Fraction By Weight: 100%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:LIQ GAS CAUSES FROSTBITE.INHAL:HI
CONCEN SYMPT-NAU,DIZZ,BRONCHIAL IRRIT,HYPOTHERMIA,INCR DEPTH OF
RESP,BRADYCARDLE,PULM DISCOMFT,PERIPHERAL
VASOCONSTRICTION,EMBLYOPIA,SEIZURES,DEATH.CHRONIC:NO KNOWN A DVERSE
EFFECTS.CONTACT W/GAS/REFRIG LIQCAUSE FROSTBITE/DMG EXPO
SKIN/EYE.ATM CONTAIN 21%OXY,HI TOXIC/PNEU,LOWER HYPOXIA
Explanation of Carcinogenicity:PER MSDS:NOT FOUND IN FED
OSHA/NTP/CAL/OSHA/IARC.
Effects of Overexposure:FROSTBITE:CHANGE IN SKIN COLOR TO WHITE OR
GRAYISH-YELLOW,PAIN AFT CONTACT W/LIQ CAN QUICKLY SUBSIDE.
Medical Cond Aggravated by Exposure:PRE-EXISTING RESPIRATORY CONDITONS
MAY AGGRAVATED BY OVER-EXPO TO THIS PRODUCT.TARGET ORGANS:RESP
SYSTEM, CNS, SKIN.

First Aid

First Aid:EMERG RESPONDERS MUST PRACTICE EXTREME CAUT.RESCUERS
SHOULDN'T ATTEMPT TO RETRIEVE VICTIM W/O PPE.MOVE TO FRESH AIR
ASAP.TRAIN PERSON ADMIN SUPPLEMENTAL OXY(NOT NORMALLY
APPROPRIATE)&/OR CPR.MOVE FROM HYPOXIC EXPO.FROSTBITE PUT PART IN
WARM WATER NOT HOT WATER,OR WRAP IN BLANKETS.ENCOURAGE TO GENTLY
EXERCISE EFFECTED PART.SEEK IMMED MED ATTN.TAKE MSDS/LABEL.DR:TREAT
SUPM/RED OVEREXPO.OVEREXPO(SUP)

Fire Fighting

Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:NON-FLAMM INERT GAS.USE EXTING MEDIA APPRORPIATE
FOR SURROUNDING FIRE.H2OSPRAY,CO2,FOAM,HALON,DRY CHEM,ANY "ABC"
CLASS.
Fire Fighting Procedures:DIRECT H2O ONTO VESSELS KEEPS THEM
COOL.SHUTOFF FLOW/MOVE VESSELS FROM FIRE SAFELY.W/D IF RISING
SOUNDS FROM VENT SAF DEV/DISCOLOR OF VESSELS OCCURS.(SUPPLEMEN)
Unusual Fire/Explosion Hazard:POWERFUL OXIDIZER.DOESNT BURN CYL IN FIRE
MAY RUPTURE/EXPLO.OXY SUPPORT/ACCELERATE COMBUST.CONTRIBUTE TO
COMBUST MATL IGN.CRYOGENIC LIQ FREEZES H2O RAPIDLY(SUP)

Accidental Release

Spill Release Procedures:USE PPE(MIN LEVEL B).CLEAR AREA/PROT
PEOPLE/RESPOND W/TRAINED PERSONNEL W/PREPLAN PROCEDURES.DONT ENTER
IF OXY >23.5%(ENTER WHEN @LEAST 19.5%-<23.5%).USE VENTI.STOP
LEAK.CRYOGENIC:CLEAR/ALLOW TO EVAPO RATE/GAS DISSIPATE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:PROT CYL AGAINST PHYS DMG.STORE IN DRY
WELL VENTI AREA AWAY FROM HEAT SOURCES,HEAVILY TRAFFI AREA,EMERG
EXITS.POST NO SMOKING SIGNS.TEMP NOT >125F.
Other Precautions:PROTECT FROM EXTREME WEATHER IF OUTSIDE.MOVE CYL
W/HND TRUCK;DONT DRAG/DROP/ROLL.SECURE CYL FIRMLY.DONT USE
OIL/GREASE ON FITTING/VALVE.MARK EMTPY/FULL.HI OXY CONTENT ATMS
COMMON COMBUST MATLS BECOME HI FLAMM.CRYO LIQ RAPIDLY BOIL TO GAS.

Exposure Controls

Respiratory Protection:MAINTAIN OXY LEVELS>19.5%/<23.5% IN WORKAREA.USE
SUPPL AIR RESP PROT IF <19.5%/EMERG RESPONSE.RESP PROT REQRUIED
FOLLOW REMQT SO OSHA 29CFR1910.134/EQUI STATE STD.DONT ENTER AREA
IF OXY CONTENT EXCEED S 23.5%.
Ventilation:USE W/ADEQU VENTI.LOC EXHAU PREFER.IF APPROPRIATE INSTALL
AUTO MONITORING EQPMT TO DETECT OXY LEVEL.
Protective Gloves:MECH RESIST FOR HNDLG,KEVLAR FOR LIQ
Eye Protection:SAF GLASS,FACE SHIELD WHEN HNDLG CYROGEN
Other Protective Equipment:USE BODY PROT APPRORPIATE FOR TASK.TRANSF LG
QUANT UNDER PRESUSRE MAY REQUIRE PROT EQPMT TO PROTECT FRM
SPLASH/EXT COLD.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIREFIGHT:STRUCTURAL FIREFIGHTERS MSUT WEAR SCBA,FULL PROT EPQTM.
FIRE/EXPLO:OXY GAS CONDENSES H2O VAPO CREATING DENSE FOG.LIQ OXY
EXPO TO ATM PRODUCE CLOUD OF ICE/FOG IN AIR. INCOMPT MATL:READILY
FOR M PEROXIDES,REFRIG LIQ CAUS ASPHALT TO IGNITE. 1STAID:SYMPT
RELIEVED QUICKLY.PROVIDE AS NEEDED IMMED SEDATION/ANTICONVL

Chemical Properties

HCC:G4
Boiling Pt:B.P. Text:-297F,-183C
Melt/Freeze Pt:M.P/F.P Text:-360F,-218C
Decomp Temp:Decomp Text:NP
Vapor Pres:GAS,AMBIET
Vapor Density:1.31 @25C
Spec Gravity:1.11
pH:NA
Viscosity:NP
Solubility in Water:4.9% @0C
Appearance and Odor:COLORLESS,ODORLESS GAS OR COLORLESS,ODORLESS
CRYOGENIC LIQ
Percent Volatiles by Volume:NP
Corrosion Rate:NP

Stability

Stability Indicator/Materials to Avoid:YES
COMBUST/FLAMM MATLS,CHLORINATED HYDROCARBONS,HYDRAZINE,RED BORON
CMPDS,ETHERS,PHOSPHINE,PBR3,PO3,F2C:CF2,CMPDS(SUPPLEM)
Stability Condition to Avoid:AVOID CONTACT W/INCOMPATIBLE MATLS.AVOID
EXPO CYL TO EXTREMELY HI TEMPS WHICH COULD CAUSE CYL TO
RUPTURE/EXPLODE.
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:GAS DISSIPATE RAPIDLY IN WELL-VENTI AREAS.WSATE
DISPO MUST BE IAW APPROPRIATE FED/STET/LOC REGS.EPA WASTE#:NA.NOT
SARA REPORTING REQMTS.CERCLA RQ:NA.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.